弱電安裝流程及規范
作(zuo)者(zhe): 更新(xin)時間:2020-06-09弱(ruo)電(dian)(dian)(dian)(dian)工(gong)程是電(dian)(dian)(dian)(dian)力(li)(li)應(ying)用(yong)(yong)(yong)(yong)的(de)一個分類(lei),電(dian)(dian)(dian)(dian)力(li)(li)應(ying)用(yong)(yong)(yong)(yong)按照電(dian)(dian)(dian)(dian)力(li)(li)輸送功率的(de)強弱(ruo)可以(yi)分為強電(dian)(dian)(dian)(dian)與弱(ruo)電(dian)(dian)(dian)(dian)兩類(lei)。建(jian)筑及建(jian)筑群(qun)用(yong)(yong)(yong)(yong)電(dian)(dian)(dian)(dian)一般指交流220V50Hz及以(yi)下的(de)弱(ruo)電(dian)(dian)(dian)(dian),主要向人們提供(gong)電(dian)(dian)(dian)(dian)力(li)(li)能(neng)源,將電(dian)(dian)(dian)(dian)能(neng)轉(zhuan)換為其他能(neng)源,例如空調用(yong)(yong)(yong)(yong)電(dian)(dian)(dian)(dian),照明用(yong)(yong)(yong)(yong)電(dian)(dian)(dian)(dian),動(dong)力(li)(li)用(yong)(yong)(yong)(yong)電(dian)(dian)(dian)(dian)等等。弱(ruo)電(dian)(dian)(dian)(dian)系(xi)(xi)(xi)統(tong)范圍(wei)很(hen)廣(guang),其中與安(an)防(fang)(fang)相關的(de)系(xi)(xi)(xi)統(tong)有(you):保(bao)安(an)監控(kong)系(xi)(xi)(xi)統(tong)、消(xiao)防(fang)(fang)報(bao)警系(xi)(xi)(xi)統(tong)、出(chu)入(ru)口控(kong)制(zhi)系(xi)(xi)(xi)統(tong)、停車(che)場收費管(guan)理系(xi)(xi)(xi)統(tong)和樓宇自控(kong)系(xi)(xi)(xi)統(tong),弱(ruo)電(dian)(dian)(dian)(dian)安(an)裝在安(an)防(fang)(fang)工(gong)程中起著(zhu)至關重要的(de)作(zuo)用(yong)(yong)(yong)(yong)。
一、 施工步驟:
1、勘察現場
A.與客戶(hu)協商,借用存(cun)放(fang)材料(liao)(liao)的(de)(de)(de)(de)(de)材料(liao)(liao)間(jian),材料(liao)(liao)間(jian)要(yao)(yao)足夠大,且距(ju)離施(shi)(shi)工(gong)現(xian)(xian)場(chang)較(jiao)近。B.水電(dian)設(she)備(bei)。現(xian)(xian)場(chang)是否(fou)具(ju)備(bei)施(shi)(shi)工(gong)必(bi)需的(de)(de)(de)(de)(de)水電(dian)設(she)施(shi)(shi)。C.電(dian)力負(fu)荷。施(shi)(shi)工(gong)現(xian)(xian)場(chang)的(de)(de)(de)(de)(de)電(dian)力線是否(fou)能(neng)匹配工(gong)程的(de)(de)(de)(de)(de)負(fu)荷要(yao)(yao)求。D.設(she)備(bei)布局。確(que)定機柜的(de)(de)(de)(de)(de)位置(zhi)、終端設(she)備(bei)的(de)(de)(de)(de)(de)安(an)裝位置(zhi)以及線路的(de)(de)(de)(de)(de)的(de)(de)(de)(de)(de)敷設(she)路逕。E.樣品式樣。明確(que)客戶(hu)的(de)(de)(de)(de)(de)要(yao)(yao)求,確(que)定樣品的(de)(de)(de)(de)(de)型(xing)號、樣式。要(yao)(yao)形成文檔(dang),客戶(hu)簽(qian)字確(que)認。F.安(an)全(quan)。原材料(liao)(liao)的(de)(de)(de)(de)(de)安(an)全(quan),施(shi)(shi)工(gong)現(xian)(xian)場(chang)的(de)(de)(de)(de)(de)防火防盜的(de)(de)(de)(de)(de)措施(shi)(shi)。
2、繪制網(wang)絡(luo)拓撲圖(tu)、布(bu)局圖(tu),交客戶方確認。
3、制定工(gong)程進度(du)(du)計(ji)劃表(biao)。列舉施工(gong)期間需要(yao)完成(cheng)(cheng)的工(gong)作(zuo)任務(wu),以及(ji)各項工(gong)作(zuo)完成(cheng)(cheng)的先(xian)后次序(xu),并(bing)確定詳(xiang)細的計(ji)劃時(shi)間,如(ru)下(xia)圖所示。工(gong)程進度(du)(du)表(biao)完成(cheng)(cheng)后需交(jiao)給客(ke)戶(hu)一份,以備(bei)客(ke)戶(hu)監督和配合。
4、指定工(gong)程負(fu)責人和(he)工(gong)程監理(li)人員,負(fu)責規劃(hua)備料,備工(gong),用戶方配(pei)合(he)要求等方面(mian)事宜,提(ti)出各部(bu)門配(pei)合(he)的(de)時間表,負(fu)責內外協(xie)調(diao)和(he)施工(gong)組織(zhi)和(he)管理(li)。
5、現場施工(gong),每日記錄施工(gong)進度(du),并根據計劃的(de)完成情(qing)況及時(shi)調整計劃,確保按工(gong)期工(gong)要求交付工(gong)程。
6、現場認證測試,制作測試報告,打印(yin)IP地址(zhi)表、路由(you)表、配置表。
7、驗收。在上述各環節中所建立和完善的文檔(dang),作為驗收資(zi)料(liao)(liao)的一(yi)部分,交客(ke)戶保存。同時公(gong)司也要留存幅本,作為客(ke)戶資(zi)料(liao)(liao),以備售后服(fu)務用。
二、布局規范:
布(bu)局(ju)(ju)是后續(xu)工作的基礎,所以一(yi)定要事先(xian)確定下來(lai),否則一(yi)旦返工,代(dai)價極高。電腦桌的高度規范(fan):小學約(yue)70CM,中(zhong)學約(yue)75CM;座位尺(chi)(chi)寸(cun)(cun)規范(fan):寬60—80CM,前后約(yue)60CM;排(pai)與(yu)排(pai)之間(jian)、列與(yu)列之間(jian)的走道預留寬度:60—100CM;布(bu)局(ju)(ju)圖必段根(gen)據場(chang)地(di)(di)、設(she)施實(shi)際盡尺(chi)(chi)寸(cun)(cun),按比例繪制,圖中(zhong)要標明詳細尺(chi)(chi)寸(cun)(cun)。確定好布(bu)局(ju)(ju)圖要給客戶(hu)簽字確認,必要時可在場(chang)地(di)(di)上勾描出布(bu)局(ju)(ju)的輪廓以獲(huo)得直觀感受。
三、布線規范(網線、電源線)
1、電纜標志內容:在電纜的護套上(shang)約以1M的間隔標明(ming)生產廠廠名或(huo)代(dai)號及(ji)電纜型號規格,制造年份,電纜長度。
2、塑料線槽(cao)及(ji)其(qi)附件型號規格(ge)應(ying)符(fu)合(he)設(she)計要求,并(bing)選用相(xiang)應(ying)的定型產品(pin)。其(qi)敷設(she)場所的環境溫度(du)不得(de)低(di)于-15攝氏度(du),其(qi)阻燃性能氧(yang)指數不應(ying)低(di)于27%。線槽(cao)內(nei)外應(ying)光滑無(wu)棱刺,不應(ying)有(you)有(you)扭曲、翹邊等變形(xing)現象,并(bing)有(you)產品(pin)合(he)格(ge)證。
3、纜(lan)(lan)線(xian)布放時(shi)應(ying)有冗余。在機柜處(chu),雙(shuang)絞(jiao)線(xian)纜(lan)(lan)預留長度(du),一般為3~6m;終端處(chu)為0.3~0.6m;光纜(lan)(lan)在設備端預留長度(du)一般為5~10m;有特(te)殊要求(qiu)的應(ying)按設計要求(qiu)預留長度(du)。
4、設(she)備間鋪設(she)活動(dong)地(di)(di)板時,板塊鋪設(she)嚴密堅(jian)固,每平方米水平允許(xu)偏(pian)差不(bu)應大于2mm,地(di)(di)板支柱牢固,活動(dong)地(di)(di)板防(fang)靜電措施的(de)接地(di)(di)應符合設(she)計和(he)產品說明要求。
5、每對對絞(jiao)線應(ying)盡(jin)量保持扭絞(jiao)狀態(tai),非扭絞(jiao)長度不(bu)應(ying)大于13mm。
6、剝除(chu)護(hu)套均不得刮傷絕緣(yuan)層,應使用專用工(gong)具(ju)剝除(chu)。
7、纜線中間不(bu)得產生接頭現(xian)象。
8、雙絞(jiao)線(xian)最(zui)長(chang)線(xian)距為100米,超(chao)過100 米的(de)可用雙絞(jiao)線(xian)中繼(ji)器(qi)連接加長(chang),每段線(xian)路(lu)中中繼(ji)器(qi)的(de)數(shu)據不能多于三個(ge)。
9、光纖傳(chuan)(chuan)輸距(ju)離(li)(li):傳(chuan)(chuan)輸速率(lv)1Gb/s,850nm,、普通50μm多模光纖傳(chuan)(chuan)輸距(ju)離(li)(li)550m,普通62.5μm多模光纖傳(chuan)(chuan)輸距(ju)離(li)(li)275m,新型50μm多模光纖傳(chuan)(chuan)輸距(ju)離(li)(li)1100m。
10、纜線的(de)彎(wan)曲半徑應符合下列規定:
a 非屏蔽4對雙絞線(xian)纜(lan)的彎曲半徑應至(zhi)少為電纜(lan)外徑的4倍在(zai)施工過程中(zhong)應至(zhi)少為8倍。
b 屏蔽雙絞(jiao)線纜的彎曲半(ban)徑應至(zhi)少為(wei)電纜外徑的6~10倍。
c 主干雙絞線纜(lan)的(de)彎曲半徑(jing)(jing)應(ying)至(zhi)少為電纜(lan)外徑(jing)(jing)的(de)10倍。
d 光纜(lan)的(de)彎曲半徑(jing)應(ying)至少(shao)為光纜(lan)外徑(jing)的(de)1.5倍(bei),在施(shi)工(gong)過(guo)程中應(ying)至少(shao)為20倍(bei)。
11、 對絞線在信息插座(RJ45)相連時(shi),必(bi)須(xu)按色標和線對順(shun)序進行卡接。插座類型,色標和編號應符(fu)T568A、T568B的規定。
12、在(zai)制作水晶頭(tou)時,電(dian)纜的(de)(de)外(wai)保(bao)護層需要壓在(zai)接(jie)頭(tou)中而不(bu)能在(zai)接(jie)頭(tou)外(wai)。因為當電(dian)纜受到外(wai)界的(de)(de)拉力(li)時受力(li)的(de)(de)是(shi)整個電(dian)纜,否則受力(li)的(de)(de)是(shi)電(dian)纜和接(jie)頭(tou)連接(jie)的(de)(de)金(jin)屬部分。
13、雙(shuang)絞線纜與接線模塊(IDC,RJ45)卡接時,應(ying)按設(she)計和廠家規定(ding)進行操作。
14、 屏(ping)(ping)蔽(bi)(bi)雙絞線纜的屏(ping)(ping)蔽(bi)(bi)層與(yu)接(jie)(jie)插件(jian)(jian)終端處屏(ping)(ping)蔽(bi)(bi)罩可(ke)靠接(jie)(jie)觸(chu),纜線屏(ping)(ping)蔽(bi)(bi)層應與(yu)接(jie)(jie)插件(jian)(jian)屏(ping)(ping)蔽(bi)(bi)罩360o圓(yuan)周接(jie)(jie)觸(chu),接(jie)(jie)觸(chu)長(chang)度不宜小于100mm。
15、每股雙膠(jiao)線兩(liang)端應粘膠(jiao)標簽并編號,以便于安裝和(he)維護。
16、交(jiao)接(jie)間、設備(bei)間提供(gong)可靠(kao)的施工電源和接(jie)地裝置。
17、施工現場臨時(shi)電源應(ying)有(you)完(wan)整(zheng)的(de)插頭.開關.插座.漏電保護器設置,臨時(shi)用(yong)電須用(yong)電纜。電源線分(fen)三(san)種顏色:火(huo)線紅色.零(ling)線蘭(lan)色.地(di)線黃(huang)色.所有(you)單向插座應(ying)該“左零(ling)右火(huo)中間地(di)“或“上火(huo)下零(ling)“連接(jie)。
18、電源(yuan)(yuan)線管(guan)從地(di)面(mian)下穿過時(shi),必(bi)須使用套(tao)管(guan)連接(jie)(jie)緊密(mi),在地(di)面(mian)下不允(yun)許有接(jie)(jie)頭,出入地(di)面(mian)處(chu)必(bi)須套(tao)用彎頭。地(di)面(mian)沒有封閉(bi)之前,必(bi)須保護(hu)好PVC套(tao)管(guan),不允(yun)許有破裂(lie)損(sun)傷,鋪地(di)板(ban)磚(zhuan)時(shi)PVC套(tao)管(guan)應被覆蓋,釘木地(di)板(ban)時(shi),電源(yuan)(yuan)線應沿墻(qiang)角鋪設,以(yi)防止電源(yuan)(yuan)線被釘子(zi)損(sun)傷。
19、 電源線走向橫平(ping)豎直,不(bu)可斜拉,防止被電錘(chui).釘子損傷。
20、各種強弱電插座(zuo)接口(kou)要(yao)(yao)盡量少。所有插座(zuo).開關要(yao)(yao)高于地面300MM以上,并且(qie)不(bu)會被推拉門家(jia)俱等物遮擋(dang)。
21、弱電線(xian)路與強電線(xian)路不允許共套(tao)一管,其間隔距(ju)離(li)為0.5m以上。
22、三相(xiang)五線(xian)制是(shi)指A、B、C、N和PE線(xian),其中(zhong),PE線(xian)是(shi)保護地線(xian),也叫安(an)全線(xian),是(shi)專(zhuan)門(men)用(yong)(yong)(yong)(yong)(yong)于(yu)接到諸如設備外(wai)殼等保證(zheng)用(yong)(yong)(yong)(yong)(yong)電安(an)全之用(yong)(yong)(yong)(yong)(yong)的(de)。應(ying)用(yong)(yong)(yong)(yong)(yong)中(zhong)最好使用(yong)(yong)(yong)(yong)(yong)標準/規范的(de)導(dao)線(xian)顏色(se)(se)(se):A線(xian)用(yong)(yong)(yong)(yong)(yong)黃***線(xian)用(yong)(yong)(yong)(yong)(yong)藍色(se)(se)(se),C線(xian)用(yong)(yong)(yong)(yong)(yong)紅色(se)(se)(se),N線(xian)用(yong)(yong)(yong)(yong)(yong)褐色(se)(se)(se),PE線(xian)用(yong)(yong)(yong)(yong)(yong)黃綠色(se)(se)(se)。
23、工程中各板塊之間的電源要盡量(liang)分開控(kong)制,盡量(liang)做到獨立供電,互不干擾。
四、設備安裝與調試
1、機柜安放位置的選擇規范
A .安全性(xing)。隱蔽,通(tong)風,最(zui)好(hao)有專用間,進出有限制(zhi)。B.可靠(kao)性(xing)。有合(he)適的電源接入(ru)點,有足夠(gou)的電力保障,維護(hu)方便。C.可用性(xing)。到(dao)各終端(duan)的線距在(zai)規范要求的范圍以內。D.經濟性(xing)。到(dao)終端(duan)線距總量(liang)最(zui)小。
2、網絡設備的安裝規范
A.網(wang)絡設(she)備(路由(you)器、交(jiao)換機(ji)等)應(ying)安裝在(zai)固定(ding)的托(tuo)(tuo)架上(shang);B.固定(ding)的托(tuo)(tuo)架一般(ban)應(ying)距地面500mm以(yi)上(shang);C.插入網(wang)絡設(she)備的電纜線要固定(ding)在(zai)托(tuo)(tuo)架或墻(qiang)上(shang),防止意 外脫(tuo)落(luo)。
3、終端設備安裝步驟
A.首先(xian)閱讀設(she)備(bei)(bei)手(shou)冊(ce)和設(she)備(bei)(bei)安(an)(an)裝(zhuang)說明(ming)書。B.設(she)備(bei)(bei)開(kai)箱(xiang)要按裝(zhuang)箱(xiang)單(dan)進(jin)(jin)(jin)行(xing)清點,對設(she)備(bei)(bei)外觀進(jin)(jin)(jin)行(xing)檢(jian)查,認真詳細地做好(hao)記(ji)錄。C.設(she)備(bei)(bei)就位。D.逐(zhu)臺設(she)備(bei)(bei)分別進(jin)(jin)(jin)行(xing)加電,做好(hao)自(zi)檢(jian)。E.逐(zhu)臺設(she)備(bei)(bei)分別聯(lian)到服務器(qi)上(shang),進(jin)(jin)(jin)行(xing)聯(lian)機檢(jian)查,出現問(wen)題應(ying)逐(zhu)一解決。有故障的設(she)備(bei)(bei)留在最后解決。F.安(an)(an)裝(zhuang)系(xi)(xi)統軟件(jian),進(jin)(jin)(jin)行(xing)主系(xi)(xi)統的聯(lian)調工(gong)(gong)作(zuo)。G.安(an)(an)裝(zhuang)各工(gong)(gong)作(zuo)站軟件(jian),各工(gong)(gong)作(zuo)站可(ke)正常上(shang)網(wang)(wang)工(gong)(gong)作(zuo)。H.逐(zhu)個解決遺留的所有問(wen)題。I.用(yong)戶(hu)按操作(zuo)規程(cheng)可(ke)任意上(shang)機檢(jian)查,熟(shu)悉(xi)網(wang)(wang)絡(luo)系(xi)(xi)統的各種功能(neng)。J.試運行(xing)開(kai)始(shi)。
五、弱電工程故障排查規范
1、根據統計,弱電工(gong)程故(gu)障(zhang)大約50%一(yi)70%與電纜(lan)(lan)有(you)關系。所以電纜(lan)(lan)本身的質量以及安裝(zhuang)質量都直接(jie)影(ying)響網絡(luo)的正常運(yun)行。網絡(luo)電纜(lan)(lan)故(gu)障(zhang)有(you)很(hen)多種,概(gai)括起來可以分為物(wu)理故(gu)障(zhang)(也可稱連接(jie)故(gu)障(zhang))和電氣性(xing)能故(gu)障(zhang)兩(liang)大類(lei)。
A.物(wu)理故(gu)障。物(wu)理故(gu)障主要是指由(you)于(yu)主觀因素造(zao)成的(de)(de)(de)可以(yi)直接觀察的(de)(de)(de)故(gu)障,多是由(you)于(yu)施工(gong)的(de)(de)(de)工(gong)藝或對網絡電纜的(de)(de)(de)意外損傷所(suo)造(zao)成的(de)(de)(de),如(ru):模塊、接頭的(de)(de)(de)線序錯誤,鏈路的(de)(de)(de)開(kai)路、短(duan)路、超(chao)長等。
B.電(dian)(dian)氣性(xing)能(neng)故障(zhang)。電(dian)(dian)氣性(xing)能(neng)故障(zhang)主要是指鏈路的電(dian)(dian)氣性(xing)能(neng)指標未(wei)達到(dao)測試標準的要求,即電(dian)(dian)纜在信(xin)號傳輸過(guo)程中達不(bu)到(dao)設計要求。影響電(dian)(dian)氣性(xing)能(neng)因(yin)素(su)除電(dian)(dian)纜材料(liao)本身的質量外(wai),還包(bao)括施(shi)工過(guo)程中電(dian)(dian)纜的過(guo)度彎(wan)曲(qu)、電(dian)(dian)纜捆綁太(tai)緊、過(guo)力拉伸和過(guo)度靠近干擾(rao)源(yuan)等,如:近端串擾(rao)、衰減、回(hui)波損(sun)耗(hao)等。
2、綜合布線的故障(zhang)多在水平(ping)區。這里穿線和(he)模塊端接較多,施工工藝因人而異(yi),建筑格(ge)局比垂直部分復雜。總體來(lai)說引起故障(zhang)有3方面。
A.產(chan)(chan)品(pin)本(ben)身的(de)(de)電(dian)氣性能,即產(chan)(chan)品(pin)的(de)(de)設(she)計(ji)與生產(chan)(chan)質量(liang)。B.工程方(fang)(fang)案的(de)(de)設(she)計(ji),根據建筑格(ge)局,對布線系統(tong)的(de)(de)設(she)計(ji)要求。C.施工工藝,這(zhe)是布線整體(ti)質量(liang)的(de)(de)體(ti)現,好的(de)(de)產(chan)(chan)品(pin)和好的(de)(de)施工方(fang)(fang)案,都要有好的(de)(de)施工完成。
3、打線的(de)常(chang)見(jian)錯(cuo)誤(wu)。打線的(de)常(chang)見(jian)錯(cuo)誤(wu)有開路(lu),短路(lu),反接(jie)(一(yi)(yi)對線中的(de)兩(liang)根交(jiao)叉了,如1對應2,2對應1)。另(ling)外一(yi)(yi)個(ge)錯(cuo)誤(wu)是(shi)跨(kua)接(jie),如1、2對應3、6。造成這(zhe)(zhe)種錯(cuo)誤(wu)的(de)原(yuan)因主要有兩(liang)個(ge)。一(yi)(yi)是(shi)電纜(lan)的(de)一(yi)(yi)端(duan)使用(yong)了T568A標準,而電纜(lan)的(de)另(ling)一(yi)(yi)端(duan)使用(yong)了T568B標準。二是(shi)在網絡的(de)實際(ji)應用(yong)中,有時(shi)需要使用(yong)這(zhe)(zhe)種跨(kua)接(jie)線。當有的(de)交(jiao)換機與交(jiao)換機進行級(ji)連時(shi)就需要使用(yong)跨(kua)接(jie)線。
另(ling)外(wai)當把PC機(ji)(ji)(ji)和PC機(ji)(ji)(ji)進行對(dui)接時(shi)(不通過交(jiao)換(huan)機(ji)(ji)(ji)),也(ye)(ye)需(xu)要使(shi)(shi)用(yong)跨接線。有的(de)(de)用(yong)戶使(shi)(shi)用(yong)了(le)跨接線時(shi)也(ye)(ye)可以(yi)上網,而使(shi)(shi)用(yong)正確接線時(shi)也(ye)(ye)能進行交(jiao)換(huan)機(ji)(ji)(ji)的(de)(de)級連。這是因為他(ta)們使(shi)(shi)用(yong)的(de)(de)交(jiao)換(huan)機(ji)(ji)(ji)是智能交(jiao)換(huan)機(ji)(ji)(ji)。這種交(jiao)換(huan)機(ji)(ji)(ji)可以(yi)自(zi)動將接線的(de)(de)繞對(dui)對(dui)調過來。但這不代表這種打線的(de)(de)方(fang)式是正確的(de)(de)。
最后(hou)(hou)還(huan)有一(yi)種錯誤就是串繞。通(tong)(tong)(tong)常(chang)造(zao)成這(zhe)種結果的(de)(de)(de)原因是1、2為一(yi)對,3、4為一(yi)對,5、6為一(yi)對,7、8 為一(yi)對。而網絡(luo)(luo)進(jin)行通(tong)(tong)(tong)訊時(shi)(shi)使(shi)用(yong)1、2和3、6,而不(bu)是3、4。這(zhe)種錯誤的(de)(de)(de)接線(xian)是無法用(yong)眼(yan)睛或萬用(yong)表來檢(jian)查(cha)出來的(de)(de)(de),因為其端(duan)至端(duan)的(de)(de)(de)連(lian)通(tong)(tong)(tong)性是正常(chang)的(de)(de)(de)。而這(zhe)種錯誤接線(xian)的(de)(de)(de)最大危害是會產生很大的(de)(de)(de)近(jin)端(duan)串擾。它不(bu)會造(zao)成網絡(luo)(luo)不(bu)通(tong)(tong)(tong),而是使(shi)網絡(luo)(luo)運行速度很慢,時(shi)(shi)通(tong)(tong)(tong)時(shi)(shi)斷。它屬(shu)于軟(ruan)故障(zhang),當網絡(luo)(luo)運行后(hou)(hou)檢(jian)查(cha)起來很麻(ma)煩。【小編(bian)溫馨提示:水晶(jing)頭備量=信(xin)息點*2*20% 網線(xian)計量估算:(最短線(xian)距(ju)+最長線(xian)距(ju))÷2×1.1×信(xin)息點總數(shu) 網線(xian)每箱標(biao)準(zhun)長度:305±5米】